The Puritan Bennett 840 Ventilator System is a critical care Ventilator intended for acute and subacute care of infant, pediatric, and adult patients. Electronically controlled and pneumatically powered, the 840 Ventilator System contains a breath delivery unit (BDU), graphical user interface (GUI), and backup power source (BPS). An optional compressor unit and cart are also available. The BDU is the core of the Ventilator. It contains the pneumatics that deliver gas and electronic and electrical systems that control pneumatics, monitor alarms, and distribute power. The Ventilator includes two independent central processing units (CPUs): one for the BDU that controls ventilation, and one for the GUI that monitors Ventilator and patient data. The GUI CPU verifies that the BD CPU is functioning properly and prevents a single fault from causing a simultaneous failure of controlling and monitoring operations. The GUI provides a communications path between the Ventilator and the operator. By using the touch screen, keys, and knob on the GUI the practitioner gives initial instructions and data to the Ventilator. The GUI CPU processes this information and stores it in the ventilator’s memory. The BD CPU uses this stored information to control and monitor the flow of gas to and from the patient. The 840 Ventilator System supplies mandatory or spontaneous breaths with a preset oxygen concentration. A mandatory breath can be pressure- or volume-controlled. A spontaneous breath allows the patient peak inspiratory flows up to 200 L/min with or without pressure support. The BPS (Backup Power Supply) provides dc power to the BDU in the event that ac power is lost. A new, fully charged BPS allows the Ventilator to function (without compressor or humidifier) for at least 30 minutes; thus, the BPS can power the Ventilator for transport purposes within the respiratory care facility. The BPS should always be connected to the Ventilator during operation. The optional compressor unit provides compressed air to the BDU, and can be used in place of wall or bottled air for normal operation. The compressor unit is powered by and communicates with the BDU.
- Puritan Bennett Ventilator Training
- Puritan Bennett 840 Ventilator Specifications
- Vc+ Ventilation Puritan Bennett 840
One moment please...
![User User](/uploads/1/2/6/3/126388059/470647105.jpg)
If you are looking for the book User manual for puritan bennett 840 in pdf format, then you've come to the right website. We present the complete edition of this ebook in ePub, doc, DjVu, txt, PDF formats. The Puritan Bennett 840 Ventilator System is a critical care Ventilator intended for acute and subacute care of infant, pediatric, and adult patients. Electronically controlled and pneumatically powered, the 840 Ventilator System contains a breath delivery unit (BDU), graphical user interface (GUI), and backup power source (BPS). An optional compressor unit and cart are also available. Volume Ventilation Plus Software Option 4-078126-00 PAV™.+ Option Kit 4-078203-00 Respiratory Mechanics Option Kit 10019218 Trending Software Option 10020408 Optional Accessories Service manual, English 4-070089-00 Puritan Bennett™ 840 Ventilator Cart and Accessories Puritan ™Bennett 840 Ventilator Cart with 1 Hr BPS 10000193. The Puritan Bennett 840 Plus ventilator is the flagship product in our line of critical care ventilators. It is highly responsive and offers superior comfort, delivering sensitive, precise breaths to critically iII neonatal through adult patients. Covidien offers one of the most comprehensive field. Page 1 “GettinG Over One MOre Hurdle” neOnatal SOftware and Screen cHanGeS The NeoMode software has enabled the use of the Puritan Bennett™ 840 ventilator on neonates and adults, providing a more consistent approach to mechanical ventilation for respiratory departments. More important, this also allows the latest technology to be used to ventilate neonatal patients.
- Parts
- Videos
DESCRIPTION
The flagship product in Covidien's line of critical care ventilators.The Puritan Bennett® 840™Ventilator System is the flagship product in Covidien's line of critical care ventilators. It is responsive to patients and offers superior comfort, delivering sensitive, precise breaths to critically ill neonatal through adult patients.
FORUMSView All (32)
Ask a New Question2Replies5 months ago | 5 months agoneed a PDF of the service manual need a PDF of the service manualReply |
-Liyana 6 months ago | 6 months agoAI and BD PCB hello,I have GUI problem and BD problem. I need an advice, can I swap the AI and BD PCB with the functioning unit to confirm the faulty part..I have two PB840 down at the moment. Really need an input. Thanks. Reply |
2Replies7 months ago | 7 months agoTidal Volume 1000ml not achieved Hai, is there any specific setting to deliver tidal volume 1000ml? I set the vent tidal volume for 1000ml, but only get vte 800ml. Or does test lung capacity influenced the reading? ThanksReply |
DOCUMENTS / MANUALSView All
FEATURES
Puritan Bennett Ventilator Training
- Technological Sophistication – With its high-performance pneumatics, dual-microprocessor electronics and DualView™ touchscreens.
- Upgradeable – The 840 Ventilator can be upgraded and customized with various software options to meet your clinical needs, today and in the future.
- Enhanced noninvasive ventilation (NIV) that improves comfort for patients and performance for clinicians. Designed for use on patients with a stable respiratory drive.
- Seamless Communications – The 840 Ventilator supports communication with all major patient monitoring and hospital information systems. It provides seamless electronic data transfer into a patient's medical record. When used with Clinivision® Mobile Patient Charting software, the package provides clinicians the opportunity to practice evidence-based medicine.
- Low Cost of Ownership – The 840 Ventilator is designed with rugged and reliable components. Its modular design provides easy serviceability.
- Best-in-class Service – Puritan Bennett offers one of the most comprehensive field service programs in the ventilator industry. Our Customer Service Engineers are dedicated to providing the highest quality of service to our ventilator customers.
Puritan Bennett 840 Ventilator Specifications
NEWSView All
Covidien Announces the Launch of Three New Platforms for its Puritan...Vc+ Ventilation Puritan Bennett 840
BOULDER, Colo. - (BUSINESS WIRE) - Covidien (NYSE: COV), a leading global provider of healthcare products and recognized innovator in mechanical ventilation and respiratory care devices, today announced that three new platforms for its Puritan Bennett 840 ventilator ― the Puritan Bennett 840 Neonatal ventilator, the Puritan Bennett 840 Universal ...